GT12
GT20
GUX20
30-T
back
|
|
|
|
GT12-T |
GT20-T |
GA20-T |
GU20-T |
GUX20-T |
30-T |
| Manufacturer Name: |
DKF112MAG1004IG |
DKF112MK1604IG |
|
DKF112MG1604IG |
DKF112MGB2004IG |
DKF132SK1904IG |
| Manufacturer Code: |
673163 |
684426 |
42976001 |
(534234002,
with forced cooling and 18kW) |
42832001 |
|
| Nominal Power: |
7.5kW
(S6 40% ED) |
12kW @ 5920rpm
(S6 40% ED) |
12kW
(S6 40% ED) |
12kW
(S6 40% ED) |
15kW
(S6 40% ED) |
14kW @ 3'510rpm
(S6 40% ED) |
| Torqe / Motor current: |
55Nm / 178A |
71Nm / 250A |
66Nm / 250A |
51Nm / 250A |
70Nm / 250A |
91Nm / 250A |
| Windings: |
8 |
8 |
7 |
6 |
6 |
|
| Voltage/Frequency: |
100V / 200Hz |
100V / 200Hz |
87.5V / 200Hz |
75V / 200Hz
(100V / 200Hz for 18kW) |
100V / 200Hz delta
173V / 200Hz star |
100V / 120Hz |
| Max. Speed: |
12'500 rpm |
12'500 rpm |
12'500 rpm |
12'500 rpm |
12'500 rpm |
9'000 rpm |
| Weight: |
25 kg |
32 kg |
32 kg |
32 kg |
38.5 kg |
43 kg |
| Stray Inductance: |
301 uH |
130 uH |
96 uH |
77 uH |
84 - 91 uH |
190 uH |
| Protection Class: |
IP 54 |
IP 54 |
IP 54 |
IP 54 |
IP 54 |
IP 54 |
All data for delta (not star) connection, if not otherwise specified
Manufacturer Code:
| 112 |
Size (diameter of machine) |
| M |
Medium Stator Length |
| I |
Induction smaller by a factor of 1.33 (less windings) |
| B |
Metal Sheet longer (ger: Blech) |
| SK |
short |
| 16 |
16 PS = 12kW |
| 04 |
Number of Poles |
| IG |
flange B-side with Sensor Bearing (compatible for AMC, possibly
Interface 64/48 is needed) |
| AMCE |
flange B-side for old speed sensor from Brusa |
|